SPDE Magic Needle

SPDE features full automation for dynamic sample extraction, desorption and analysis using the CTC Combi PAL. A gas-tight 2.5mL syringe is equipped with a special needle that is coated on the inside with an extraction phase. The phase can be applied in varying degrees of thickness. The adsorption process is best described as follows: A liquid or headspace sample is drawn up into a 2.5mL syringe, thereby adsorbing analytes onto the stationary phase. A distribution balance is reached between the liquid sample matrix and the active phase. The analytes are concentrated onto the phase by repeatedly moving the plunger up and down, thereby forcing the headspace or fluid through the needle. Fast plunger speeds ensure a quick exchange of sample near the active phase.

After adsorption, the syringe picks up carrier gas from the fiber bakeout station (if necessary, the station is also used to dry the coating and syringe). Then, the autosampler moves the syringe over to the hot GC inlet, and the analytes are desorbed. Additional gas flow from the syringe forces the analytes into the inlet, thereby ensuring sharp peak shapes. This technique can be used with splitless flow for maximum sensitivity.

 

- Dynamic extraction of liquid and gaseous samples

- Use of various phases and film thickness

- No mechanical or thermal stress

- High-grade steel capillary needle, which adds to its robustness

- Analyze a sample while extracting the next one

- Fully automatic use with a standard PAL system and any chromatographic system with split/splitless injector

- No extra thermal desorption system needed

- Total control of all extraction parameters

- More convenient than other extraction methods

- Less time necessary for sample incubation

- Needle coated on the inside walls with a choice of phases and variable thicknesses

- Optimized sample contact with the phase is reached by setting the number of plunger pumpings, resulting in shorter incubation time 

DESCRIPTION REFERENCE
 SPDE Option with SMM 1 syringe, 2 coated needles and purging station (heated version)  Requires Cycle Composer, small mixing bars and PAL TraySet 20 mL  PAL SPDE  Opt-20
 SPDE Option with SMM 1 syringe, 2 coated needles and purging station (Peltier version)  Requires  Cycle Composer, small mixing bars and PAL TraySet 20 mL  PAL SPDE  Opt-P
 SPDE syringe 2,5 mL, RN-type (removable needle tip)  SPDE-  Syr204250
 SPDE Needle with phase coatings: removable needles available in 2 lengths: To order long  needle:  standard 56 mm or 74 mm for use with SPDE Extraction Cooler only  To order long  needle:
 Needle, PDMS, 50 µm, 56 mm (or 74 mm)  SPNdl-1-50-  56
 Needle, PDMS/activ charcoal, 50 µm, 56 mm (or 74 mm)  SPNdl-1/AC-  50-56
 Needle, PEG (Carbowax), 50 µm, 56 mm (or 74 mm)  SPNdl-WAX-  50-56
 Needle, CT 5 (5 % Diphenyl / 95 % Dimethylsiloxan), 50 µm, 56 mm (or 74 mm)  SPNdl-5-50-  56
 Needle, 1701 (14 % Cyanopropyl / 86 % Dimethylsiloxan), 50 µm, 56 mm (or 74 mm)  SPNdl-1701-  50-56
 Needle, OV 225 (25 % Phenyl-25 % Cyanopropylmethylsilicon, 50 % PDMS) 50 µm, 56 mm  (or  74  mm)  SPNdl-225-  50-56