4100 Solid and Liquid injections
The OI Analytical 4100 Water / Soil Sample Processor automates the handling and processing of samples in 40-mL VOA vials for purge-and-trap analysis of volatile organic compounds (VOCs) in accordance with U.S. EPA methods. The 4100 efficiently processes up to 100 drinking water, wastewater, or soil samples and operates with a single or dual Eclipse 4660 purge-and-trap instruments.
The 4100 is equipped with an innovative pneumatically-actuated cylindrical vial gripper that surrounds and conforms to each vial. The VOA Constrictor™ mechanism lifts and transports 40-mL VOA vials to and from the sampling station with unsurpassed reliability.
- Holds 100 samples in two 50-position vial racks
- Operates with one or two Eclipse 4660 purge-and-trap instruments
- Vial cooling option keeps vials at 10°C or less in accordance with USEPA Method 524.3
- VOA Constrictor™ vial gripper has built-in vial sensor
- Standard Addition Module has two 3-mL reservoirs, expandable to four 3-mL reservoirs
- High-speed injection valves in Standard Addition Module inject programmed volume with no excess or waste
Purge-and-Trap Compatibility |
Operates with one or two Eclipse 4660 instruments |
Sample Capacity |
100 standard USEPA 40-mL VOA Vials |
Sample Loop |
5mL standard loop, 10 or 25 mL loops optional |
Automated Standard Addition |
(2) 3mL reservoirs standard, expansion to (4) optional |
Sampling Mode – Water |
Aspiration and transfer to purge-and-trap instrument sparge vessel |
Sampling Mode – Soil |
In-vial needle sparging and transfer to trap of purgeand-trap instrument |
Sample Transfer Pathway – Water Samples |
Silcosteel 316L stainless steel and PEEK |
Sample Transfer Pathway – Soil Samples |
Silcosteel 316L stainless steel and PEEK |
Blank Water Transfer |
PFA–Teflon |
Vial Trays |
(2) 50-position VOA vial trays |
Vial Gripper Mechanism |
Pneumatically actuated cylindrical gripper with vial sensing |
Vial Cooling Option |
Cooling base for two 50-position vial trays with quickdisconnect fittings for recirculating chiller |
X/Y-Axis Mechanism |
Digitally controlled linear drive rails |
Z-Axis Mechanism |
Pneumatically actuated |
Operating Software |
VOA View Windows-based GUI |
Operating System |
Windows 7or Windows 8 and 8.1 |
PC to 4100 Communications |
USB port for each 4100 instrument connected to PC |
Water Supply |
Clean, VOC-free water for rinsing sample pathway |
Gas Requirements - Sample Transfer |
99.999% (UHP Grade) He or N2 |
Gas Requirements - Gripper / Z-axis Actuator |
Nitrogen |
Power Requirements |
110VAC / 60HZ or 230VAC / 50Hz |
Dimensions |
27 in. W x 24 in. D x 21.5 in. H 68.6 cm W x 61 cm D x 54.6 cm H |
Weight |
36 Kg (80 lbs) , typical depending on options |
Certifications |
CE Safety and EMC EN50082-1/EN55011 Group 1 Class A |