Aquatek 100
The AQUATek 100 is a purge and trap autosampler that automates the sample preparation steps for the analysis of liquid samples utilizing a fixed volume sample loop filled using a pressurization gas. Two independent volume programmable internal standards are then added to the sample and the entire aliquot is transferred to the Purge and Trap for compound concentration and subsequent separation and detection using a GC/GC-MS quantification system.
The AQUATek 100 brings to market the latest engineering enhancements that have been employed in Tekmar’s latest sample preparation lines. In addition, newer materials in the field of inertness and advanced intelligent software controls have been incorporated. These features combined with greater vial capacity and increased sample handling speed will offer customers greater flexibility and increased throughput to help their production needs all while maintaining a low cost of ownership.
- 30% more sample capacity with its 100-vial carousel for standard 40mL vials
- Auto blanking is now available without sacrificing sample positions on the carousel thus allowing utilization of every vial space on the carousel for samples
- Built in chilling feature that gives the customer the flexibility of using this feature if their needs call for it without any added cost
- Two - 15mL UV-protected standard spiking vessels to prevent compound breakdown. Capable of varying volume delivery in 1, 2, 5, 10, and 20µL aliquots with zero waste
- Unique slide out Plumbing Access Compartment (PAC)
- Interchangeable loop system available in 5mL, 10mL, 20mL, and 25mL sizes
- Automated diagnostics and leak check
- Customized TekLinkTM software package integrates the Autosampler and Purge & Trap for seamless operation
- Entire liquid pathway can be rinsed using the patented high temperature OptiRinse cleaning techniques
- Built-in Chiller tray allows sample cooling (recirculating bath required)
- Pressurized water reservoir for Blanking and System Rinsing included
- Inert sample path comprised entirely of PEEKTM tubing
Automation | |
Sample Types | Liquid samples, including drinking water and wastewater; Liquid samples containing up to 15 mm of sediment when measured from the bottom of an upright 40 mL vial |
Sample Vials | 100-positions for 40 mL VOA vials, single hole cap with Teflon faced silicone septum, per EPA specifications |
Vial Transport Device | Carousel/Piercing Needle design using stepper motors and optical encoders for accurate positioning. |
Liquid Handling | |
Sample Liquid Handling | Sample loop dispenses fixed volumes of water determined by the installed sample loop. Sample loops are available in 5 mL, 10 mL, 20 mL, and 25 mL volumes. |
Sample Precision | < 1% RSD (n=7 @ 5 mL delivery volume measured by weight) |
Sample Path | PEEK™, EPDM and Ultem® for solenoid valve. 1/16” (0.16 cm) OD PEEK™ tubing for liquid transfer |
Water Supply | Requires use of a pressurized blank water reservoir (included) |
Cleaning | The entire liquid pathway can be rinsed using the high temperature OptiRinse (patented) cleaning technique which uses two internal reservoirs to heat blank water up to 90 °C for rinse. User defined rinses for the needle and glassware. |
Gas Handling | |
Sample Gas Pathway | 1/16” & 1/8” O.D. PEEK™ tubing; 1/8” Teflon Tubing |
Gas Supply | Ultra-high Purity (99.999%) pure Helium or Nitrogen; Incoming Pressure: 60-100psi, (100psi max) |
Standard Injection | |
Standard Injection System | Two standard injection systems utilizing 2-way dosing valves mounted on a valve manifold. |
Capacity | Up to 20 μL in 1, 2, 5, 10 & 20 μL increments. |
Precision | < 10% RSD measured by GC/FID for Fluorobenzene and Bromofluorobenzene, (n=7). Based on 5 µL injection volume. |
Accuracy | 1 µL ± 0.1 µL. |
Consumption | 1 µL per 1 µL injection. |
Standard Vessels | Two 15 mL standard vessels, UV-protected for added standard stability; Standard vessels sealed under pressure for standard concentration integrity. |
Samples | |
Blanks | Automatic blanks can be pulled from the blank water reservoir and spiked with standard/ surrogate allowing all autosampler positions to be used for samples. |
Vial Cooling | Cools sample tray to 4 °C as defined by most EPA Methodologies (requires an external recirculating cooling bath). |
Cooling Bath Connection | Inlet and outlet hose connections require 1/4” (0.64 cm) ID rubber tubing. |
Heater | |
Hot Water Heater | Variable Heat Control from 35 °C to 90 °C. |
System Control | |
Instrument Control | VOC TekLink™ 2G software in a Windows® XP or greater environment via RS-232 or USB to RS-232 converter (optional). |
Language | VOC TekLink™ 2G can easily be translated into any language via file modification. |
Method Storage | Infinite method storage including pre-programmed methods. |
Method Scheduling | Water samples can be run from any position in the sample sequence. Up to two standards/ surrogates can be added to any user-specified position. |
System History | The system records a complete history of all sample, schedule and method information. |
Revision Control | The system records and saves changes to methods, schedules and configurations. |
Service | |
Electronic Leak Check | Ability to leak check the sample pathway of the system via an automated system leak check process. |
Benchmark Test | The system has a mode that will allow for full electromechanical testing including; valving, heater, vial handling systems, liquid delivery system, inputs and outputs |
Diagnostics | The system offers independent control of all valves and vial handling mechanisms and for troubleshooting. |
E-mail Alert | The system can be configured to send an E-mail to alert the user of schedule completion or stoppage. |
General Specifications | |
Dimensions (H x W x D) | 28.5” x 18”x 19” (72.39 cm x 45.72 cm x 48.26 cm) |
Weight | Unit weight: 39 lbs (17.69 kg); Shipping weight: 100 lbs (45.36 kg) |
Power Requirements | 100-240VAC, 50/60 Hz, 2.5A, 300VA |
Environmental Specifications | Operating Temperature: 10° to 30 °C; Storage Temperature: - 20° to 60 °C; Relative Humidity: 10% to 90% |
Corrosion Resistance | The carousel tray is corrosion resistant to waters with a pH range of 1 to 10. |
Certifications | CE, CETL, CSA, ETL |
pH Probe Specifications | |
pH Range | 0 to 14 |
Power Requirements | 4.5 to 5.5 Vdc |
Operating Temperature | 0o to 70 oC |
Accuracy | +10% with two point calibrated range |
Dimensions | Length: 7.48” Diameter: 0.63” |