1290 Infinity II Variable Wavelength Detector
World’s most sensitive and fastest variable wavelength detector
The Agilent 1290 Infinity II Variable Wavelength Detector (VWD) is the world’s most sensitive and fastest detector in its class. Time-programmable wavelength switching provides optimum sensitivity and selectivity for your applications. Even more sample information can be acquired in the dual wavelength mode. Lowest detector noise (<± 1.5 µAU) and baseline drift (< 1 x 10-4 AU/h) facilitates precise quantification of trace levels components. Ultraproductivity can be achieved with fast analysis at up to 240 Hz data rates.
-
Lowest baseline noise and drift results in lowest detection limits for robust quantification of trace level components.
-
Dual-wavelength capabilities offer more analyte information per run.
-
Up to 100% resolution gain in ultrafast LC, at up to 240 Hz data acquisition rate.
-
Wide linear range (>2.5 AU upper limit) - for reliable, simultaneous quantification of primary compounds, by-products and impurities.
-
Electronic temperature control (ETC) – for maximum baseline stability and practical sensitivity under fluctuating ambient temperature and humidity conditions.
-
Automatic wavelength verification provided through the use of built-in holmium oxide filter.
-
Radio frequency identification (RFID) technology for flow cells and lamps provides a new level of data traceability.
-
Early maintenance feedback (EMF) for continuous tracking of instrument usage, in terms of lamp burn time, with user-defined limits and message types.
-
Extensive diagnostics, error detection and displays provided using Agilent Lab Advisor software.
-
Stop-flow wavelength scanning for fast wavelength optimization.
Specifications Agilent 1290 Infinity Variable Wavelength Detector (G1314E) |
|
Detection type |
Double-beam photometer |
Light source |
Deuterium lamp |
Number of signals |
1 |
Maximum data rate |
240 Hz |
Noise |
< ±0.15 x 10 -5 AU, at 230 nm* |
Drift |
< 1 x 10-4AU/hr, at 230 nm |
Linearity |
>2.5 AU upper limit |
Wavelength range |
190-600 nm |
Wavelength accuracy |
± 1 nm, self-calibration with deuterium lines, verification with holmium oxide filter |
Slit width |
6.5 nm typical over whole wavelength range |
Time programmable |
Wavelength, polarity, peak width, lamp on/off |
Flow cells |
Standard: 14 µL volume, 10 mm cell path length |
Spectral tools |
Stop-flow wavelength scan |
Analog output |
Recorder/Integrator 100 mV or 1 V, 1 output |
Communication |
LAN, Controller-area network (CAN), |
GLP |
Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user settable limits and feedback messages. Electronic records of maintenance and errors. Data recovery card to prevent data losses. RFID for electronics records of flow cell and UV lamp conditions (path length, volume, product number, serial number, test passed, and usage). Verification of wavelength accuracy with built-in holmium oxide filter. |
Safety and maintenance |
Extensive diagnostics, error detection and display through Agilent Instant Pilot and Agilent Lab Advisor software. Leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. Tracking of flow cells and lamps with RFID (radio frequency identification) tags |